Title | LUM licenses donโt show up in EasyAdmin |
Category | Broker |
Date | Nov 11, 2011 |
Handled by | |
Relevant Links | http://bug.openlm.com/view.php?id=225 |
Applies to license managers | LUM |
Applies to license model | Floating licenses, Network licenses, Concurrent licenses, Node Locked |
Symptoms | LUM licenses donโt show up in EasyAdmin. |
Observed during dubug | 1. The Broker was not sending any information to the OpenLM Server 2. The Broker “test connectivity” button clicked: Broker saw the OpenLM Server OK. |
Trouble shoot process | 1. Upgraded Broker version. 2. Changed the I4BLT.EXE path from the OpenLM folder to one supplied by the application vendor. |
Solution | Found (Found/Pending/Known Issue) |
Symptom
LUM licenses donโt show up in EasyAdmin.
Solution
1. Upgrade the OpenLM Broker on the license server machine. Refer to the Application Note for reference.
2. As part of the OpenLM package, the latest version of the I4BLT.EXE file is supplied. This file may not be inter-operable (version too new) with the licensed application version. If this is the case, please follow these steps:
Changing a single portโs configuration
- Open the OpenLM Broker configuration tool.
- Select the relevant License server.
- Check the โUpdate to the following pathโ radio button
- Click the โEditโ button. The text box becomes active.
- In the โPathโ text box, type in the path of the I4BLT.EXE file in the LUM folder, originally supplied by the application vendor.
This configuration change may also be achieved by individually typing the I4BLT.EXE file path in each Broker command text box.
Changing all portsโ configurations
- Open the OpenLM Broker configuration tool.
- Click the โAdvanced Settingsโ wrench icon. The Advanced settings window opens.
- Click the โEditโ button. The text boxes become active.
- In the โI4BLT Pathโ text box, type in the path of the I4BLT.EXE file in the LUM folder, originally supplied by the application vendor.
- Select a specific portโs โCommandsโ list item. The โCommandsโ window opens.
- Check the โUpdate according to advanced settingsโ radio button, and click the โUpdateโ button. The I4BLT path of the specific port is changed.
- Repeat steps 5 & 6 for all ports.