Title | Failed to close application via the “Close Application” button on the “Active Products” window |
Category | Agent and extensions |
Date | Mar 01, 2012 |
Handled by | Rachel |
Relevant Links | (link to mantis item, docs, customer correspondence etc.) |
Applies to license managers | FLEXlm, FLEXera FLEXnet, IBM LUM, HASP, RLM, Sentinel RMS |
Applies to license model | Floating licenses, Network licenses, Concurrent licenses |
Symptoms | AutoCAD application was not closed after clicking the “Close Application” button on the “Active Products” window |
Observed during investigation | In the OpenLM Server log file: the server reports it โCould not find license id for product <product name>โ. |
Trouble shoot process | 1. Create a role. 2. Assign all the necessary resources, that will allow viewing details, to the new role. 3. Add users as members of this role. |
Solution | Found (Found/Pending/Known Issue). |
Symptoms
AutoCAD application was not closed after clicking the “Close Application” button on the “Active Products” window.
Some Background…
- When required to shut down an application, EasyAdmin web application sends the โCloseApplicationโ request over to the OpenLM server.
ย
- The OpenLM server writes this Closure request to a table in the OpenLM database, and should receive a โSuccessโ response.
ย
- The Active Agent requests a periodic update in the โCycleInfo messageโ. It is informed it should shut down the application.
ย
- The OpenLM server then searches the look-up table in the database for a match between the required feature (Product) and a process name.
ย
- The problem is that process names tend to change. This causes the Agent not to recognize the process name, and the application fails to shut down.
ย
Observed during investigation
Currently – there is no method of identifying this problem, other than inspecting the OpenLM Server logs. Please set the OpenLM Server logging level to โALLโ , compress the entire log directory and send it to support@openlm.com.
Solution :
The solution to this issue is to update the OpenLM database, and fix the Look-up table so that the product would point to a correct process name.
This update is done through an XML file, which OpenLM needs to generate. This file should be run in the following way:
1. Get the XML file from OpenLM. Save it to a temporary directory.
2. On the OpenLM server configuration tool, select the ‘Advanced’ tab, and click the “Update products feature table” button. The ย “Update products features” window opens.
3. Click the “Update from file” radio button, and type in the xml file with its full path.
4. Click the ‘Update’ button, ‘Apply’ and ‘restart server’.
See the following image for clarification.