71453: Some terminals generated much larger Workstation Agent log files than expected. Log output on affected terminals now matches normal expected behavior.
63019: Added support for Linux network users whose home directories are located outside /home/ (e.g., centralized/LDAP users with paths like /enp/home/users/). The Linux installer now correctly detects and supports these users.
69744: Added support for encrypted Client Authorization files in the Workstation Agent. The Agent can now load and decrypt authorization files provided by the Identity Service, ensuring sensitive credentials are no longer stored in plain text on disk. Existing unencrypted files continue to work without changes.
67628: Fixed excessive log entries generated every 2 seconds for suspended processes that matched window title tracking rules. Suspended processes are now correctly excluded from window title filtering.
68708: Fixed MATLAB startup error caused by a .NET runtime conflict between the OpenLM MATLAB extension (.NET Framework) and third-party extensions such as dSPACE (.NET 8). Agent extensions have been upgraded to .NET Framework 4.6 to resolve the incompatibility.
70635: Fixed named pipe server initialization failure in the AutoCAD 2025 extension running on .NET 8.
65897: Fixed Project environment variable value not refreshing after the initial read. The Agent now reads the environment variable value on-demand instead of caching it at startup, ensuring project assignments always reflect the latest value.
66546: Added Use Dongle Monitoring checkbox for Cloud mode.
67509: Fixed Dongle Monitoring state during silent upgrade.
67293: Eliminated User Account Control (UAC) prompt after SCCM-based installation. Workstation Agent service now starts automatically after reboot without triggering a UAC prompt, including on workstations where users have local administrator rights.
65230: Fixed an issue where Workstation Agents connecting to the EU Cloud used the wrong PD address.
38576: Fixed an issue where the Show Project UI message was invoked one minute later than the interval defined in the Administration > Projects settings.
64248: Suspended processes were not cleared from Personal Dashboard after PC shutdown.
63019: Linux Workstation Agent failed to start and report usage data for network-managed users with home directories outside /home/.
63126: Update to .NET 8.
63060: Silent Script installation - Checkbox selection issue.
61857: Security update.
60844: Disconnected time appears for a usage while dongle is still connected.
Note: This release applies exclusively to the Windows installer. The tar.gz, deb, and rpm versions remain unchanged.
59567: Workstation Agent installer - MATLAB extension fails to load.
60586: The ArcGIS Pro extension remains registered after uninstalling the Workstation Agent.
Note: This release applies exclusively to the Windows installer. The tar.gz, deb, and rpm versions remain unchanged.
57217: Windows installer: Error installing ArcGIS Pro Extension for ArcGisPro v3.3.0 or later.
54289: Ability to detect Solidworks 2024.
52487: The 'Timed out connecting to the pipe for process' error in Live Feed caused issues with configuring License Harvesting.
44522: The selected authentication files are not saved if the source is a network drive.
51081: The screenshots capture more than just a process window.
51672: The Agent Extension saves new documents for ArcScene / ArcGlobe with .mxd extension instead of .sxd / .3dd extension.
52295: When upgrading and selecting the authentication file from 'shared' on upgrade, it goes to backup file and the current is not updated.
52299: When upgrading, the backup files for 'authorization' and 'settings' are not updated correctly.
51080: Added possibility to disable captured screenshots.
50073: Unstable behavior when repeatedly launching and closing AUTOPIPE.
51421: Silent Agent installation with Cloud mode and USEDONGLEMONITORING=true should correctly set useDongleMonitoring to "true" in settings.json and update the dongle address according to the authorization file.
50785: The installation of the Agent fails when User Account Control (UAC) is enabled.
50602: ArcMap Extension encounters issues when attempting to resume new untitled documents.
49642: Silent installation incorrectly sets the useDongleMonitoring parameter to "true" in the settings.
49306: The Save and Close fails for Catia.
49171: The Workstation Agent fails to report a dongle if it's connected before adding its vendor to the Dongle Monitoring system.
45661: Security settings fail to update correctly during software upgrades.
47280: Improved management and control capabilities for Bentley applications.
43424: Personal Dashboard & Workstation Agent: The Recently Closed through Suspension method session cannot be cleared.
47642: Timeout exception error.
47278: Enhanced license management capabilities for Bentley products, allowing tracking and control usage at both the application and feature levels.
46760: When upgrading, the security and authorization file are not updated during a silent installation.
46367: The "InstallMatlabExtensionAction" in the installer is failing.
45236: When AutoCAD is in the foreground and it has been suspended, the window does not minimize.
46812: When Agent fails to get process start time in the ProcessCycleInfoAsync, the process's start time is incorrectly showing as January 1, 2000.
46812: When we're unable to find the start time of a process, the process's start time is incorrectly showing as January 1, 2000.
42688: Silent Installation option that installs the Workstation Agent without Start Menu Shortcut.
43172: Wrong session Start Time.
44793: Workstation Agent tar.gz install.sh script issues.
45239: AppSettings misconfiguration after upgrading.
44282: The Workstation Agent fails to prompt for elevation (msi).
41111: Force user to select the project before or within 1 minute of using the application.
43020: When App Manager becomes unreachable, monitoring processes are lost.
40952: Upgrading from v5 to v22, Server settings are not updated in installer v22.
41938: 'UseEndUserServices' value is not updated properly in settings file.
25058: Implement missing UpdateScreenShot, multiplatform.
37648: Implement monitoring a Dongle Existence once a day.
38195: Migrate Workstation Agent to .NET 6.
41721: Workstation Agent installation without EUS possibility.
41816: Support for Solidworks 2023.
41394: Whenever a device is connected/disconnected an event is raised multiple times.
41515: Incorrect address for Dongle Monitoring.
41524: Error when installing Autocad Plugin.
41573: Change log level: When log level is changed in Personal Dashboard, in Agent settings it is not updated.
41832: Personal Dashboard: When a screenshot for released processes is removed from the folder, the icons are still displayed in PD.
41841: Linux - System.TypeInitializationException EntityFrameworkCore.
40392: Added silent parameter useDongleMonitoring.
41456: Filter path trackings for App Manager by session ID.
38928: EUS - unresponsive and showing 0 total quantity after adding more than 70 applications in Application Manager.
39491: Workstation Agent: Installer does not load extension for ArcGIS Pro 3.
38038: Workstation Agent closes an application without reaching the Idle Time.
38675: Agent: Installer: EUS 'Use SSL' is not updated in settings.json.
38495: End-User Services: don't filter Agents by IP.
37636: Agent: Installer, remove select EUS host and port.
34634: Agent Linux - Add Dashboard shortcut.
33602: Ability to check connectivity with services in installer.
37947: Application Manager not working from external Agents.
38251: Autocad extension is not detected when installing Agent through system account.
36727: Prevent Agent Silent install to open a web page to connect to the Personal Dashboard.
38250: Installation fails.
38197: Agent process does not start after upgrade.
37680: Agent: MATLAB extension causes MATLAB to freeze.
37549: Agent - Save and close Solidworks issues.
35758: Agent installer now includes a separate screen to set up EUS connection details.
37036: End-User Services: Installer: Unable to go back on Installation step.
36974: End-user Services: Installer: No SSL configuration is displayed for Cloud mode.
36707: Suspension not firing when user is logged off.
36565: "Stop tracking" disables AppManager products.
36481: Agent: App Manager log only prints intercepted / monitored process names.
35187: "Add license" became available notification.
28650: SSL connection with OpenLM Server can be configured during the installation.
36318: Unmanaged processes: AgentSuspend procedure performed twice.
36317: Force users to choose a project whenever the InvokeProjectsUI message is sent.
Compatibility: 35423: AutoCAD Plugin - Agent: Do not allow to install both Agent and AutoCAD Plugin.
33609: Added field to display imported authorization file.
32033: End-User Services - support Open Folder.
33493: Avoid blocking the installation of a New Agent instance if a legacy Agent is already installed.
35929: Minor UI Issues.
35928: Application Manager 'useSSL' setting is updated on 'true', even if not checked in installer.
35858: Installer fails to kill elevated Agent instances.
35708: The Agent does not verify correctly the authorization file based on operation mode.
35665: New Agent: Standard account requires Admin rights.
35593: Agent Installer doesn't detect Solidworks 2022.
35563: Solidworks - No Active Agent or Idle Times. Close App is grayed out and App Idle time stays at N/A.
35482: Upgrading the Agent to the latest version causes SSL settings loss and requires reissuing a new Auth file.
35133: Missing buttons in the wizard while upgrading.
35132: During upgrade some files went missing.
34964: The Agent keeps monitoring a process when its parameters are changed.
34809: Agent and EUS Linux installers are overwriting settings files on upgrade.
34104: The Agent creates user account with a blank username.
33179: Agent: File path for Save&Close actions is not displayed.
35748: Agent - SSL Changes.
29555: Allow selecting the App Manager settings both silently or via installer UI.
34042: Add Variable names in the Application Manager definitions.
33718: OpenLM Extension not getting installed for Solidworks 2019.
30287: Agent: Catia support for "save and close".
33639: The Unmanaged App is minimized.
20600: Agent: Disable access to "open folder" in recently closed documents.
26772: Agent: Solidworks 2020 extension not checkable on install.
23232: Agent: InvalidOperationException when OpenLM Server is stopped and ArcGisPro levels form is displayed.
22281: Agent: Single Suspended pop-up window when multiple Autocad sessions are suspended, instead of each per session.
20442: Active Agent for Matlab should not interfere with customer environment.
19899: Legacy Agent: EasyAdmin shows 2 users when a second Agent runs on PC under another Windows account.
29416: Support for ArcGIS 10.8.1.
26665: Disabling "Log projects information" doesn't affect Agent.
26603: Set active project still available when Environmental Value is set.
25907: Set active project pop-up appears frequently and cannot be suppressed.
24803: Restart of the Agent changes current project to "No Project".